PDI Unique ID Compatibility

Overview

Versal PDI files carry two identifiers in the image header:

  • unique_id (offset 0x24) identifies the PDI itself.

  • parent_unique_id (offset 0x28) identifies the base design the PDI was built against.

A reconfigurable partition is built against one specific base design, and parent_unique_id records which. The partition is compatible with a running base design when the partition’s parent_unique_id matches that base design’s unique_id.

Diagnosis is therefore a matter of reading both values and comparing them.

The build log and dfx-mgr both call these identifiers UUIDs. This page uses the image-header field names instead, because that is what bootgen prints and what the offsets refer to.

Finding the Unique IDs

From the Yocto Build Log

PL firmware recipes that inherit meta-xilinx/meta-xilinx-core/classes-recipe/dfx_user_dts.bbclass record both identifiers while installing the firmware.

The message is a build note, so it is written to the task log rather than to the console. Search the log after a build:

$ grep "PL firmware UUID" tmp*/work/*/*/*/temp/log.do_install
NOTE: PL firmware UUID: <design>.pdi unique_id=<id> parent_unique_id=<parent-id>

The log exists only if do_install ran. A recipe restored from sstate writes none, and the search returns nothing. Force the task with bitbake -f -c install <recipe> and search again.

From a PDI File

Read the image header directly with bootgen. On a host, bootgen comes from a Vitis or Vivado installation and is not on the default PATH; inside a Yocto build it is provided by bootgen-native.

$ bootgen -arch versal -read <design>.pdi ih

Both identifiers appear in the IMAGE HEADER output, two fields to a line, each paired with an unrelated one:

              id (0x18) : 0x18700002           unique_id (0x24) : 0x9ad61dc1
parent_unique_id (0x28) : 0x7308088e         function_id (0x2c) : 0x00000000

A PDI holding more than one image prints one such pair per image.

Match the -arch argument to the device family. Note that bootgen spells these differently from SOC_FAMILY:

SOC_FAMILY

bootgen -arch

versal

versal

versal-net

versalnet

versal-2ve-2vm

versal_2ve_2vm

versal-2vp

versal_2vp

This is the same source the build log reports, so the two methods return identical values for a given PDI.

Querying a Running Target

dfx-mgr reports both identifiers and a compatibility verdict. Run the client as root on the target:

# dfx-mgr-client -listPackage -all

The listing opens with the boot PDI’s PL identifier, in both the default and -all views:

boot.pdi PL UUID: 657c3dde

dfx-mgr reads it once at startup, so it describes the boot PDI rather than whatever is loaded now, and reports N/A off Versal. It also reports N/A on Versal where the boot PDI was built without a unique_id, which is common: the field is then zero and no image matches.

Three columns carry the per-package values, all needing -all:

Column

Contents

UUID

The package’s own identifier, from the PDI metaheader on Versal and the JSON uid field elsewhere.

Parent UUID

What it was built against: the parent shell for a DFX accelerator, the boot PDI for a Versal flat design.

Pid

The verdict from comparing the two.

Pid carries one of three values:

Value

Meaning

id_ok

The package’s pid matches the base design’s uid.

id_err

Both values are present and they do not match.

no_id

One or both values are absent, so no comparison was made.

Read Parent UUID against the right reference. A DFX accelerator’s is its shell’s own UUID, a value the listing does not show; read it from the shell PDI. A flat design’s is the boot.pdi PL UUID header, and is never compared: a flat base always reports id_ok whatever the values, so check it by eye.

On Versal the listing and the offline routes therefore report the same identifiers: a base design’s come from the PDI in its directory, a partition’s from the PDI in its slot directory.

A package built for a different device can still appear in the listing. dfx-mgr reads each metaheader with the PLM’s device ID (IDCODE) check bypassed, and nothing in the listing marks the package as foreign; its Pid can still read id_ok. Loading it fails, because the PLM enforces the IDCODE check at load time and reports XLOADER_ERR_GEN_IDCODE (0x326). That is a different fault from id_err.

Interpreting a Mismatch

dfx-mgr does not itself stop a package load on a mismatch. It logs one line and programs the partition anyway:

base(<base>).uid = <value> does NOT match accel(<rm>).pid = <value>

The daemon prefixes its own name, function, and line number, and prints the values as signed decimal where the build log and bootgen use hexadecimal, so an identifier with its top bit set prints negative. A match prints the same line with the NOT removed.

dfx-mgr makes no comparison for a bitstream loaded directly with dfx-mgr-client -b, and logs none. Its UUID and Parent UUID read N/A and its Pid reads -. That includes a partial forced with --force onto a base design dfx-mgr did not load, such as the boot PDI. Only the PLM check below applies.

The PLM applies its own check as it loads the partition. Where the partition’s parent identifier does not match the one the PLM holds for the loaded parent image, it refuses the load and reports XLOADER_ERR_INCOMPATIBLE_CHILD_IMAGE (0x353). That check is skipped for a partition carrying no identifier of its own or no parent identifier, and for images that are neither PL nor AIE. On versal-net and versal-2ve-2vm it covers PL images only. Where it is skipped the partition runs against a base design it was not built for, which can present as wrong results or a hang with nothing naming the cause. Read Pid before loading rather than after.

Rebuild the partition against the base design the target runs, or load the base design the partition was built against.

To confirm the two values independently of the daemon, read them from the PDI files as described in Finding the Unique IDs.

Limitations

  • Versal only. Zynq-7000 and Zynq UltraScale+ bitstreams carry no image-header identifiers. dfx-mgr still shows the columns on Zynq UltraScale+, but fills them from shell.json and accel.json, so they describe the packaging rather than the bitstream.

  • bootgen cannot read the image header of a PDI whose metaheader is encrypted. Query the target instead; the PLM decrypts the header with the device’s own key.

  • The build-log route covers only recipes that inherit dfx_user_dts.bbclass, and is best effort. A PDI that is missing or unreadable produces no message rather than a build failure, and where a recipe has PDIs in more than one location only the first is reported, so an absent message is not conclusive. Read the PDI directly instead.